v4.2 [Oct 16, 2014]
-Added support for HiTemp140-FR, PRTemp140.
-Added support for IFC203.
-Added alarm acknowledging.
-Added alarm details to alarm log and email notifications.
-Multiple alarm notifications can now be selected.
-Fixed calibration display not updating in the Device Properties dialog after calibrating.
-Fixed crashing when saving a report containing a Last Value statistic.
-Fixed installer not running when selecting the same non-English language as the current Windows language.
-Other minor fixes.
v4.1 [Mar 5, 2013]
- Added support for RFCurrent2000A, RFPRHTemp2000A, LyoTemp
- Added ambient temperature selection when calibrating pHTemp101 and pHTemp2000
- Added Sum statistic for pulse devices.
- Process101A data displays in milliamps by default.
- Alarm and trigger settings are displayed in the device's engineering unit if it has one.
- Saving a report to database for the first time will bring up a folder selection dialog.
- Cooling flags can be enabled for graphs that contain more than one dataset.
- Reports that were previously saved to file will default to "Save to file" in the save prompt that appears when closing the software.
- When configuring "Time above" and "Time below" statistics, only the currently displayed units are available for selection.
- "Time above" and "Time below" statistics will automatically update the unit when a channel unit changes.
- Timestamps have been added to messages in the Batch Start dialog.
- Device engineering units should no longer automatically import when they match existing units.
- Thermocouple channels use the correct color preference.
- Excel chart title is the report title.
- Excel tab names include the report title.
- Excel chart series names include device identifiers based on the "Channel Grouping" selection in the software.
- "Manage Axis Positions" has been renamed to "Axis Positions".
- "Set Cooling Flags" has been renamed to "Cooling Flags".
- "Manage Math Channels" has been renamed to "Math Channels".
- Fixed HiTemp140 extended range values being clamped to 260 °C.
- Fixed changes to display settings not writing after settings have been applied once and the Device Properties dialog hasn't been closed.
- Fixed calibration wizard miscalculating the gain and offset for pHTemp101 and pHTemp2000 when using high/low values.
- Fixed crashing when a QuadTemp or OctTemp with disabled channels encounters an interruption in communication during real time.
- Fixed occasional freezing when a wired device is plugged back in after being disconnected during real time.
- Fixed device ID not writing when a single device is started.
- Fixed alarm popups displaying both high and low alarm conditions as being met when an RF2000A series device alarm is triggered.
- Fixed annotations appearing on every reading when a Cryo-Temp or TransiTempII is running in real time.
- Fixed crashing when cooling flags are enabled and non-temperature data is added to a report.
- Fixed datasets not restoring from the recycle bin if they were originally in a report before being deleted.
- Fixed new reports saving to database after saving to file.
- Fixed graphs not updating the Updated column in the report list when the background color, view, or annotations are modified.
- Fixed data tables printing all data when a timeslice is created.
- Fixed changes to Reading column in data tables not saving.
- Fixed pulse rate unit descriptions not displaying correctly.
- Fixed display settings not writing if the LCD turns on or off while changing settings.
- Fixed engineering units with negative gains not displaying correctly and sometimes not writing.
- Fixed engineering units not appearing in unit preferences after being created until the software is restarted.
- Fixed statistics views not saving changes when statistics are added or removed.
- Fixed column widths and statistic property changes in statistics views not saving.
- Fixed column reordering in data tables and statistics views not saving.
- Other minor fixes.